PLMS PHOTOPIC LAMP MEASUREMENT SYSTEMS
Accurate, easy-to-use systems for measuring total luminous flux
FEATURES:
- NIST Traceable Calibrated Spectral Flux Lamp Standard
- Spectraflect® Interior
- External Forward Flux Port
- Latch-free Clamshell Design
- CIE Recommended Geometry for Total and Partial Flux
Labsphere's PLMS Photopic Lamp Measurement Systems are integrating sphere photometers designed to measure the total luminous flux of lamps.
The systems are capable of measuring all lamp types including arc, fluorescent, incandescent and HID. Available in 10, 20, 40, 65 and 76 inch diameter integrating sphere sizes, each diameter accommodates a particular class of lamp defined by its physical size and output flux rating. The interior of the spheres are coating with Spectraflect® Diffuse Reflectance Coating which combines 98% reflectance with nearly perfect Lambertian properties.
PLMS Systems conform to the recommendations of CIE Publication 84, providing easy-to-operate highly accurate measurement systems.
Download Large PLMS Datasheet
Download Medium PLMS Datasheet
The PLMS integrating sphere includes a 3 inch satellite sphere with an integral baffle cosine collector and photopic response detector. This assembly offers a wide field of view, necessary for accurate total flux measurement. A precision-regulated DC power supply provides highly accurate currents for lamp standard measurements. The SC 6000 radiometer/photometer operates out-of-the-box, with a 64 digit back lit display that allows users to view measurement results, select calibration factors and set display features and remote communication parameters.
The cosine receiver with an integrated photometer collects the average sphere wall radiance. The sphere design enables testing within CIE recommended geometries, reducing errors associated with directional lamps. The lamp standards of total luminous flux provide NIST traceable results with every measurement. An optional auxiliary lamp corrects for device under test (DUT) absorption differentials for added precision.
A Calibrated Luminous Flux Standard is supplied with each PLMS traceable to National Institute of Standards and Technology (NIST).
Ordering Information and Specifications – Mid Size Spheres
| Model Number/Description |
PLMS-10 |
PLMS-20 |
| Medium PLMS Photopic Light Measurement Systems |
AS-02477-100 |
AS-02478-100 |
System Includes:
|
|
|
| LMS-100 or LMS-200 Lamp Measurement Sphere |
AS-02477-000 |
AS-02478-000 |
| Calibrated Lamp, CL-600 |
AS-01332-000 |
AS-01332-000 |
Lamp Socket Assembly
|
AS-02477-004 |
AS-02478-002 |
| LPS-100-0260, 2.60 A, 35 W, Preset Power Supply* |
AS-02600-260 |
AS-02600-260 |
| Photopic Detector, SDA-P |
AS-02522-001 |
AS-02522-001 |
| Radiometer/Photometer, SC 6000 * |
AS-02702-000 |
AS-02702-000 |
|
|
|
| *Product sheets are available for additional information |
|
|
|
|
| System Properties and Performance |
|
|
| Sphere Diameter: |
10 in (25 cm) |
20 in (50 cm) |
| Sphere Coating Reflectance: |
98% 98% |
|
| Radiometric Range: |
100 W (max) |
400 W (max) |
| Photometric Range: |
600 mlm – 2000 lm |
2 – 6,500 lm |
| Max Recommended DUT Dimension: |
1 x 1 in (3 x 3 cm) |
2 x 2 in (5 x 5 cm) |
| Sphere Weight: |
8 lbs (3.6 kg) |
21 lbs (9.5 kg) |
| Sphere Dimension:(W x D x H) |
16.7 x 11 9 x 15.5 in |
28.5 x 23.7 x 29.4 in |
|
42.4 x 30.2 x 39.4 cm |
72.4 x 60.2 x 74.7cm |
|
|
|
| Detector |
Vl Filter Silicon Photodiode |
Vl Filter Silicon Photodiode |
| Active Area: |
5.7 mm2 |
5.7 mm2 |
| Range: |
Visible |
Visible |
| f1’: |
4% |
4% |
| Connector: |
Triax |
Triax |
|
|
|
| Radiometer/Photometer |
SC 6000 |
SC 6000 |
| Power Requirements: |
110./220 VAC, 50/60 Hz |
110./220 VAC, 50/60 Hz |
| Current Dynamic Range: |
1pA - 1mA |
1pA - 1mA |
| Voltage Dynamic Range: |
10mVdc – 50Vdc |
10mVdc – 50Vdc |
| Computer Interface: |
Ethernet |
Ethernet |
| Detector: |
Vl Filter Silicon |
Vl Filter Silicon |
| Photodiode Active Area: |
5.7 mm2 |
5.7 mm2 |
| Range: |
Visible |
Visible |
| f1’ : |
4% |
4% |
| Connector: |
Triax |
Triax |
|
|
|
| Lamp Standard |
CL-600 |
CL-600 |
| Power: |
35 W |
35 W |
| Approximate Luminous Flux: |
450 lm |
450 lm |
| Rated Life: |
300 hrs |
300 hrs |
| Calibration: |
Total Luminous Flux (lumens) |
Total Luminous Flux (lumens) |
| Power Supply |
LPS-100-0260, 2.60 A, 35 W |
LPS-100-0260, 2.60 A, 35 W |
| Power Requirements: |
110./220 VAC, 50/60 Hz |
110./220 VAC, 50/60 Hz |
| Current Stability: |
0.10% |
0.10% |
| Current Rise Time: |
20 s |
20 s |
| Regulated Current: |
2.60 A +/- 0.1% |
2.60 A +/- 0.1% |
| Weight: |
6.5 lbs (2.9 kg) |
6.5 lbs (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1x 26.7 x 8.9 cm |
21.1x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| Optional Accessories |
|
|
| Absorption Correction Lamp, AUX-35 |
AS-02639-000 |
|
| Calibrated Luminous Flux Standards Set, ,CLFS-600 |
AS-01337-000 |
|
| Bayonet Lamp Socket Assembly, LMP-1100 SC |
AS-02477-004 |
|
| 50 mm Precision Aperture, PA-200-050 MM, |
AS-02487-050 |
|
| Horizontal Lamp Mount Bracket |
AS-02477-003 |
|
| Preset Power Supply, LPS-100-0260, 2.60 A, 35 W |
AS-02600-260 |
|
| Preset Power Supply, LPS-100-0307, 3.07 A 35 W |
AS-02600-307 |
|
Ordering Information and Specifications – Large Size Spheres
| Model and Description |
40 in. (1.02 m) |
65 in. (1.6 m) |
76 in. (2 m) |
| Photopic Light Measurement Systems, PLMS Large |
AS-02479-100 |
AS-02480-100 |
AS-02481-100 |
| System Includes 40 in. (1.02 m) 65 in. (1.6 m) 76 in. (2 m) |
|
|
|
| Light Measurement Sphere |
AS-02479-000 |
AS-02480-000 |
AS-02481-000 |
| CL-1400, Luminous Flux Standard |
AS-01342-000 |
AS-01342-000 |
AS-01342-000 |
| Min Screw Lamp Socket Assembly |
AS-02236-000 |
AS-02236-000 |
AS-02236-000 |
| LPS-150-0268, Lamp Power Supply |
AS-02656-268 |
AS-02656-268 |
AS-02656-268 |
| SDA-P, CE, Photopic Detector |
AS-02522-001 |
AS-02522-001 |
AS-02522-001 |
| Radiometer/Photometer, SC 6000 * |
AS-02702-000 |
AS-02702-000 |
AS-02702-000 |
|
|
|
|
| System Properties and Performance |
|
|
|
| Sphere Diameter: |
40 in (1.02 m) |
65 in (1.6 m) |
76 in (2 m) |
| Sphere Coating Reflectance: |
98% |
98% |
98% |
| Radiometric Range: |
1500W (max) |
4000W (max) |
5000W (max) |
| Photometric Range: |
10 lm – 30000 lm |
20 lm – 70000 lm |
30 lm – 100 klm |
| Max Recommended Lamp Dimension: |
4 x 4 in(10x10 cm) |
7 x 7 in(18x18 cm) |
8 x 8 in(21x 21cm) |
| Maximum Tubular Lamp Length: |
24 in (60 cm) |
34 in (86 cm) |
52 in (1.3 m) |
| Sphere Weight: |
187 lbs (84.7 kg) |
600 Lbs (272 kg) |
800 lbs (363 kg) |
| Sphere Dimension: (W x D x H) |
48.9x42.3x68.5 in |
112.6x78.4x84.1 in |
116.9x88.2x91.4 in |
|
1.24x1.07x1.74 m |
2.86x1.99x2.13 m |
2.97x 2.24x2.32 m |
| Detector |
Vl Filter Silicon Photodiode |
Vl Filter Silicon Photodiode |
Vl Filter Silicon Photodiode |
| Active Area: |
5.7 mm2 |
5.7 mm2 |
5.7 mm2 |
| Range: |
Visible |
Visible |
Visible |
| f1’: |
4% |
4% |
4% |
| Connector: |
Triax |
Triax |
Triax |
|
|
|
|
| Radiometer/Photometer |
SC 6000 |
SC 6000 |
SC 6000 |
| Power Requirements: |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz 110/220 VAC, 50/60 Hz |
|
| Current Dynamic Range: |
1pA - 1mA |
1pA - 1mA |
1pA - 1mA |
| Voltage Dynamic Range: |
10mVdc – 50Vdc |
10mVdc – 50Vdc |
10mVdc – 50Vdc |
| Computer Interface: |
Ethernet |
Ethernet |
Ethernet |
| Detector: |
Vl Filter Silicon |
Vl Filter Silicon |
Vl Filter Silicon |
| Photodiode Active Area: |
5.7 mm2 |
5.7 mm2 |
5.7 mm2 |
| Range: |
Visible |
Visible |
Visible |
f1’:
|
4% |
4% |
4% |
| Connector: |
Triax |
Triax |
Triax |
|
|
|
|
| Lamp Standard |
CL-1400 |
CL-1400 |
CL-1400 |
| Power: |
75 W |
75 W |
75 W |
| Approximate Luminous Flux: |
1400 lm |
1400 lm |
1400 lm |
| Rated Life: |
2000 hrs |
2000 hrs |
2000 hrs |
| Calibration Total Luminous Flux: |
Lumens |
Lumens |
Lumens |
| Power Supply: |
LPS 150-0268
|
LPS 150-0268 |
LPS 150-0268 |
| Power Requirements: |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz |
| Current Stability: |
+/- 0.01% |
+/- 0.01% |
+/- 0.01% |
| Current Rise Time: |
20 +/- 5 seconds |
20 +/- 5 seconds |
20 +/- 5 seconds |
| Regulated Current: |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
| Weight: |
6.5 lbs (2.9 kg) |
6.5 lbs (2.9 kg) |
6.5 lbs (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
CE |
|
|
|
|
| Optional Accessories |
|
|
|
| Lamp Assembly, AUX-100 |
AS-02737-000 |
|
|
| Preset Power Supply 8.33A 100W, LPS-100-0833 |
AS-02600-833 |
|
|
| LPS Mounting Kit |
AS-02482-000 |
|
|
| Calibrated Luminous Flux Set, CLFS-1400 |
AS-01344-000 |
|
|
| Spectrally Calibrated Lamp Set, CSFS-1400 |
AS-01343-000 |
|
|
| 50mm Precision Aperture, PA-200-050MM |
AS-02487-050 |
|
|
| Diode Array Spectrometer, DAS-110 |
AS-01682-100 |
|
|
| Diode Array Spectrometer, DAS-210 |
AS-01684-100 |
|
|
|
|
Print PDF of this page



|
|