Labsphere
Contact Us | Partner Login
Online Store

CSLMS Choice Spectral Lamp Measurement Systems

Spectral Lamp Measurement Systems

FEATURES:

  • NIST Traceable Standards for In-house Recalibration
  • Spectral Results in Milliseconds
  • LightMtrX® Measurement Software
  • Spectraflect® Interior
  • CIE Recommended Geometry

MEASURE:

  • Total Spectral Flux (Watts/nm)
  • Total Radiant Flux (Watts)
  • Total Luminous Flux (lumens)
  • Color (CCT)
  • Color Ellipses and Quadrangles
  • Lamp Performance vs. Time
  • Peak and Dominant Wavelength
  • Spectral Purity
  • Color Rendering Index (CRI)
  • Chromaticity Coordinates
  • FWHM

APPLICATIONS:

  • LEDs
  • Miniature Lamps
  • LED Sourced Systems

Labsphere continues to set the pace in the industry with its CSLMS Spectral Lamp Measurement Systems, which provide total spectral flux solutions. Featuring our high-end spectrometers and LightMtrX® Software, combined with our light measurement spheres and lamp standards, CSLMS Spectral Lamp Measurement Systems are the optimum choice for spectral flux measurements. The heart of these systems is either the CDS 1100 or CDS 2100 Spectrometer coupled with Labsphere's application based software. The base design of these spectrometers is the proven Crossed Czerny-Turner spectrograph with a top-of-the-line thermal electrically cooled back thinned illuminated CCD detector designed for highly efficient stray-light rejection. Carrying over the best features of our industry proven spectrometers while addressing today's industries needs, these spectral engines include user activated integrated shutters for real-time dark correction and intuitive software modules for research, development and production.

Systems are available with sphere sizes ranging from 10 to 76 inches in diameter to accommodate various device types and sizes. The systems can be expanded to include an auxiliary lamp for the correction of absorption error to ensure accurate test results. National Institute of Standards and Technology (NIST) traceable total spectral flux standards enable simple in-house system calibration and verification. The CSLMS Spectral Lamp Measurement Systems are easily customized through a variety of interchangeable light measurement accessories.

Download CSLMS Medium Datasheet

Download CSLMS Large Datasheet

LIGHT MEASUREMENT INTEGRATING SPHERE DESIGN

The CSLMS light measurement integrating spheres have a latch-free clamshell design for easy access to the device under test (DUT). The base portion admits additional cables for assembled fixtures while the external port provides for a unobstructed positioning of board mounted or heat-sinked devices for forward flux and partial flux measurements. A telescopic lamp mount can be repositioned with a quick twist for base up, base down or horizontal lamp positioning. Exchangeable baffles give optimal detector screening efficiency while quick connect internal and external electrical contacts allow for effortless substitution between devices under test.

The interiors of the integrating spheres are coated with Spectraflect® Diffuse Reflectance Coating which combines a 98% reflective surface with nearly perfect Lambertian reflectance. Both durable and highly stable, Spectraflect® provides consistent integration of light over the lifetime of your sphere.

EASY TO USE

All CSLMS Spectral Measurement Systems combine intuitive operating software with high-speed hardware to simplify complex measurements. The coupling of application specific software with a CCD-based spectrometer (wavelength ranges 250-850 nm or 350-1050), integrating sphere and cosine receiver makes it possible to collect total spectral flux, luminous flux, radiometric flux and colorimetric data in milliseconds.

OPERATING SOFTWARE

LightMtrX-SPEC software

The Windows®-based LightMtrX-SPEC Software® guides users through testing, providing straightforward testing procedures and repeatable results to meet the needs of both new users and experienced researchers. DLL drivers are standard with the LightMtrX® platform, including examples written for today's most popular programming languages. When you are ready to increase your capacity, the integral design and user graphical interface make it easy to transition from research to production.

Software Functions and Features

  • Menu Driven Operation
  • User Calibration and Validation Processes
  • Display, Log, and Store Results for Research
  • Pass/Fail Testing for Production
  • Temporal Plots for Life Performance

CHOOSE FROM:

CSLMS SPECTRAL LAMP MEASUREMENT SYSTEMS - Medium Systems
10 and 20 inch diameter integrating spheres to accommodate devices from 1 x1 inch (3 x 3 cm) to 2 x 2 inches (5 x 5 cm)

CSLMS SPECTRAL LAMP MEASUREMENT SYSTEMS - Large Systems
40, 65 and 76 inch diameter integrating spheres to accommodate large devices and arrays from 4 x 4 inches (10 x 10 cm) up to 8 x 8 inches (21 x 21 cm).

CSLMS SPECTRAL LAMP MEASUREMENT SYSTEMS - Medium Systems

Ordering Information and Specifications


Description and Model  CSLMS 1011  CSLMS 1021
10 inch Spectral Lamp Measurement System

with CDS 1100 or 2100  AS-02477-600 AS-02477-700



System Includes:

Light Measurement Sphere, LMS 100  AS-02478-000  AS-02478-000
Spectrally Calibrated Lamp, SCL-600 AS-01335-000  AS-01335-000
Lamp Socket Assembly  AS-02478-002  AS-02478-002
Preset Power Supply, LPS-100-0260, 2.60 A, 35 W  AS-02600-260  AS-02600-260
CCD Array Spectrometer, CDS 1100 or CDS 2100  AS-02746-100  AS-02746-200
MtrX-SPEC Spectral Light Measurement Software, required, sold separately
Light MtrX Light MtrX



System Properties and Performance




Sphere Size: 10 in (25 cm) 10 in (25 cm)
Sphere Coating Reflectance: 98% 98%
Radiometric Range: 100 W (max)  100 W (max)
Photometric Range: (Illuminant A)  560 mlm – 12500 lm  385 mlm – 8500 lm
Red LED Range: 95 mlm – 2100 lm  100 mlm – 2200 lm
Green LED Range: 335 mlm – 7450 lm  375 mlm – 8400 lm
Blue LED Range: 140 mlm – 3050 lm  145 mlm – 3100 lm
Spectral Range: 350 - 850 nm  350 - 1050 nm
Max Recommended DUT Dimension: 1 x 1 in (3 x 3 cm)  1 x 1 in (3 x 3 cm)
Sphere Weight: 8 lbs (3.6 kg)  8 lbs (3.6 kg)
Sphere Dimension: (W x D x H)  16.7 x 11 9 x 15.5 in  16.7 x 11 9 x 15.5 in 

42.4 x 30.2 x 39.4 cm 42.4 x 30.2 x 39.4 cm



Spectrometer CDS 1100  CDS 2100
Detector: 1044 x 64 CCD (back thinned)  1044 x 64 CCD (back thinned)
Spectral Range: CCD TE Cooled 250-850 nm  350-1050 nm
Resolution: 1.5 FWHM  1.5 FWHM
Integration Time: 8 ms – 40 s  8 ms - 40 s
Cooling: 10 +/- 0.05 C  10 +/- 0.05 C
TE Temp Drift: +/- 1 C  +/- 1 C
Linearity: +/- 0.5%  +/- 0.5%
Wavelength Accuracy: <+/- 0.4 nm  <+/- 0.4 nm
Stray Light Broadband: <10-4 at 400nm w/ Ill A source  <10-4 at 400nm w/ Ill A source
Stray Light LED/Laser: <10-5 at 500nm w/633 nm laser  <10-5 at 500nm w/633 nm laser
Focal Length: 100 mm  100 mm
Optical Input: 600 mm, 3m long (SMA Connection)  600 mm, 3m long (SMA Connection)
Speed: 0.1 scans /sec 0.1 scans /sec
Dynamic Range: (single scan)  30000:1  30000:1
Spectral Sample Interval: 0.25nm  0.25nm
Mechanical Shutter: Yes  Yes
AD Converter: 16 bit  16 bit
PC Interface: USB 2.0  USB 2.0
Trigger : 11.3 lbs (5.04 kg)  11.3 lbs (5.04 kg)
Dimensions: (W x D x H): 8.3 x 13.0 x 3.5 in  8.3 x 13.0 x 3.5 in 

21.1 x 32.9 x 8.9 cm 21.1 x 32.9 x 8.9 cm



Lamp Standard SCL-600  SCL-600
Power:
35 W 35 W
Approximate Luminous Flux: 450 lm  450 lm
Rated Life: 300 hrs  300 hrs
Calibration: Spectral Flux (W/nm)  Spectral Flux (W/nm)

350 - 1050 nm  350 - 1050 nm



Power Supply LPS-100-0260, 2.60 A, 35 W  LPS-100-0260, 2.60 A, 35 W
Power Requirements: 110/220 VAC, 50/60 Hz  110/220 VAC, 50/60 Hz
Current Stability: 0.10% 0.10%
Current Rise Time: 20 s  20 s
Regulated Current: 2.60 A +/- 0.1%  2.60 A +/- 0.1%
Weight: 6.5 lbs (2.9 kg)  6.5 lbs (2.9 kg)
Dimension: (W x D x H)  8.3 x 10.5 x 3.5 in  8.3 x 10.5 x 3.5 in

21.1 x 26.7 x 8.9 cm 21.1 x 26.7 x 8.9 cm
Compliance: CE  CE



Optional Accessories

Sphere Photometer Temperature Probe, TP-100 AS-02637-100
Sphere Photometer Monitor and Probe, TPM-100 AS-02638-100
35W Absorption Correction Lamp, AUX-35  AS-02639-000

Ordering Information and Specifications


Description  CSLMS 2011  CSLMS 2021
20 inch Spectral Lamp Measurement System

with CDS 1100 or 2100  AS-02478-600  AS-02478-700



System Includes:

Light Measurement Sphere, LMS 200  AS-02478-000 AS-02478-000
Spectrally Calibrated Lamp, SCL-600  AS-01335-000  AS-01335-000
Lamp Socket Assembly  AS-02478-002  AS-02478-002
Preset Power Supply, LPS-100-0260, 2.60 A, 35 W  AS-02600-260  AS-02600-260
CCD Array Spectrometer, CDS 1100 or CDS 2100  AS-02746-100  AS-02746-200
MtrX-SPEC Spectral Light Measurement Software, required, sold separately
Light MtrX Light MtrX



System Properties and Performance

Sphere Size: 20 in (50 cm)  20 in (50 cm)
Sphere Coating Reflectance: 98% 98%
Radiometric Range: 400 W (max) 400 W (max)
Photometric Range: (Illuminant A) 2.25 lm – 50000 lm  1.55 lm – 34000 lm
Red LED Range: 375 mlm – 8400 lm 395 mlm – 8800 lm
Green LED Range: 1.35 lm – 30000 lm  1.50 lm – 33700 lm
Blue LED Range: 550 mlm – 12000 lm  570 mlm – 12700 lm
Spectral Range: 350 - 850 nm  350 - 1050 nm
Max Recommended DUT Dimension: 2 x 2 in (5 x 5 cm)  2 x 2 in (5 x 5 cm)
Sphere Weight: 21 lbs (9.5 kg)  21 lbs (9.5 kg)
Sphere Dimension: (W x D x H) 28.5 x 23.7 x 29.4 in  28.5 x 23.7 x 29.4 in 

72.4 x 60.2 x 74.7cm 72.4 x 60.2 x 74.7cm



Spectrometer  CDS 1100  CDS 2100
Detector TE Cooled: 1044 x 64 CCD (back thinned)  1044 x 64 CCD (back thinned)
Spectral Range: 250-850 nm  350-1050 nm
Resolution: 1.5 FWHM  1.5 FWHM
Integration Time: 8 ms – 40 s  8 ms - 40 s
Cooling: 10 +/- 0.05 C  10 +/- 0.05 C
TE Temp Drift: +/- 1 C  +/- 1 C
Linearity:
+/- 0.5% +/- 0.5%
Wavelength Accuracy: <+/- 0.4 nm  <+/- 0.4 nm
Stray Light Broadband: <10-4 at 400nm w/ Ill A source  <10-4 at 400nm w/ Ill A source
Stray Light LED/Laser: <10-5 at 500nm w/633 nm laser  <10-5 at 500nm w/633 nm laser
Focal Length: 100 mm  100 mm
Optical Input: 600 mm, 3m long (SMA Connection)  600 mm, 3m long (SMA Connection)
Speed: 0.1 scans /sec  0.1 scans /sec
Dynamic Range: (single scan)
30000:1  30000:1
Spectral Sample Interval: 0.25nm  0.25nm
Mechanical Shutter: Yes  Yes
AD Converter: 16 bit  16 bit
PC Interface: USB 2.0 USB 2.0
Trigger: 11.3 lbs (5.04 kg)  11.3 lbs (5.04 kg)
Dimensions: (W x D x H) 8.3 x 13.0 x 3.5 in  8.3 x 13.0 x 3.5 in 

(21.1 x 32.9 x 8.9 cm 21.1 x 32.9 x 8.9 cm



Lamp Standard  SCL-600  SCL-600
Power: 35 W  35 W
Approximate Luminous Flux: 450 lm  450 lm
Rated Life:
300 hrs 300 hrs
Calibration: Spectral Flux (W/nm)  Spectral Flux (W/nm)

350 - 1050 nm  350 - 1050 nm



Power Supply LPS-100-0260, 2.60 A, 35 W  LPS-100-0260, 2.60 A, 35 W
Power Requirements: 110/220 VAC, 50/60 Hz  110/220 VAC, 50/60 Hz
Current Stability: 0.10% 0.10%
Current Rise Time: 20 s  20 s
Regulated Current: 2.60 A +/- 0.1%  2.60 A +/- 0.1%
Weight: 6.5 lbs (2.9 kg)  6.5 lbs (2.9 kg)
Dimension: (W x D x H) 8.3 x 10.5 x 3.5 in  8.3 x 10.5 x 3.5 in

21.1 x 26.7 x 8.9 cm  21.1 x 26.7 x 8.9 cm
Compliance: CE  CE



Optional Accessories

Sphere Photometer Temperature Probe, TP-100  AS-02637-100
Sphere Photometer Monitor and Probe, TPM-100  AS-02638-100
35W Absorption Correction Lamp, AUX-35  AS-02639-000

CLSMS-SPECTRAL LAMP MEASUREMENT SYSTEMS – Large Systems

Ordering information and Specifications


CSLMS LED  - 40 inch Sphere  CSLMS 4011
CSLMS 4021
Choice Spectral Lamp Measurement System  AS-02479-600  AS-02479-700
System Includes:

Lamp Measurement Sphere, 40 inch  AS-02479-000  AS-02479-000
CCD Array Spectrometer, CDS 1100 or 2100  AS-02746-100  AS-02746-200
Spectral Calibrated Lamp, SCL-1400  AS-01342-000  AS-01342-000
Lamp Power Supply, LPS-150-0268  AS-02656-268  AS-02656-268
MtrX-SPEC Spectral Light Measurement Software, required, sold separately Light MtrX Light  MtrX
Operating System: Windows XP, VISTA and 7 Windows XP, VISTA and 7



System Properties and Performance

Sphere:  LMS-400  LMS-400
Sphere Diameter: 40 in (1.02 m)  40 in (1.02 m)
Sphere Coating Reflectance:  98% 98%
Radiometric Range:  1,500 W (max)  1,500 W (max)
Photometric Range: (Illuminant A)
2 – 72,500 lm  2 – 72,500 lm
Red LED Range: 0.62 – 26,000 lm  0.62 – 26,000 lm
Green LED Range:  0.60 – 28,500 lm  0.60 – 28,500 lm
Blue LED Range: 0.25 – 8,900 lm  0.25 – 8,900 lm
Max Recommended Lamp Dimension:  4 x 4 in (10 x 10 cm) 4 x 4 in (10 x 10 cm)
Maximum Tubular Lamp Length: 24 in (60 cm) 24 in (60 cm)
Sphere Dimension: (W x D x H)
48.9 x 42.3 x 68.5 in  48.9 x 42.3 x 68.5 in

(1.24 x 1.07 x 1.74 m)  (1.24 x 1.07 x 1.74 m)



Spectrometer  CDS 1100  CDS 2100
Detector TE Cooled: 1044 x 64 CCD (back thinned)  1044 x 64 CCD (back thinned)
Spectral Range: 250-850 nm  350-1050 nm
Resolution: 1.5 FWHM  1.5 FWHM
Integration Time: 8 ms – 40 s  8 ms - 40 s
Cooling: 10 +/- 0.05 C  10 +/- 0.05 C
TE Temp Drift: +/- 1 C  +/- 1 C
Linearity:
+/- 0.5% +/- 0.5%
Wavelength Accuracy: <+/- 0.4 nm  <+/- 0.4 nm
Stray Light Broadband: <10-4 at 400nm w/ Ill A source  <10-4 at 400nm w/ Ill A source
Stray Light LED/Laser: <10-5 at 500nm w/633 nm laser  <10-5 at 500nm w/633 nm laser
Focal Length: 100 mm  100 mm
Optical Input: 600 mm, 3m long (SMA Connection)  600 mm, 3m long (SMA Connection)
Speed: 0.1 scans /sec  0.1 scans /sec
Dynamic Range: (single scan)
30000:1  30000:1
Spectral Sample Interval: 0.25nm  0.25nm
Mechanical Shutter: Yes  Yes
AD Converter: 16 bit  16 bit
PC Interface: USB 2.0 USB 2.0
Trigger: 11.3 lbs (5.04 kg)  11.3 lbs (5.04 kg)
Dimensions: (W x D x H) 8.3 x 13.0 x 3.5 in  8.3 x 13.0 x 3.5 in 

(21.1 x 32.9 x 8.9 cm 21.1 x 32.9 x 8.9 cm



Power Supply  LPS 150-0268  LPS 150-0268
Power Requirements:  110./220 VAC, 50/60 Hz  110./220 VAC, 50/60 Hz
Current Stability: +/- 0.01%  +/- 0.01%
Current Rise Time: 20 +/- 5 seconds  20 +/- 5 seconds
Regulated Current: 2.679 A +/- 0.1%  2.679 A +/- 0.1%
Weight: 6.5 lbs. (2.9 kg)  6.5 lbs. (2.9 kg)
Dimension: (W x D x H) 8.3 x 10.5 x 3.5 in  8.3 x 10.5 x 3.5 in

21.1 x 26.7 x 8.9 cm 21.1 x 26.7 x 8.9 cm
Compliance: CE  CE



Optional Accessories

Sphere Photometer Temperature Probe, TP-100  AS-02637-100
Sphere Photometer Monitor and Probe, TPM-100  AS-02638-100
35W Absorption Correction Lamp, AUX-35  AS-02639-000

SPECIFICATIONS AND ORDERING INFORMATION

CSLMS 65 inch Sphere CSLMS 6511
CSLMS 6521
Choice Spectral Lamp Measurement System  AS-02480-600  AS-02480700
System Includes:

Lamp Measurement Sphere, 65 inch  AS-02480-000  AS-02480-000
CCD Array Spectrometer, CDS 1100 or 2100  AS-02746-100  AS-02746-200
Spectral Calibrated Lamp, SCL-1400  AS-01342-000  AS-01342-000
Lamp Power Supply, LPS-150-0268  AS-02656-268  AS-02656-268
MtrX-SPEC Spectral Light Measurement Software, required, sold separately LightMtrX LightMtrX
Operating System: Windows XP, VISTA and 7 Windows XP, VISTA and 7



System Properties and Performance

Sphere: LMS-6500  LMS-6500
Sphere Diameter: 65 in (1.65 m)  65 in (1.65 m)
Sphere Coating Reflectance: 98% 98%
Radiometric Range: 4,000 W (max)  4,000 W (max)
Photometric Range: (Illuminant A) 6 – 200,000 lm 6 – 200,000 lm
Red LED Range: 1.2 – 68,000 lm  1.2 – 68,000 lm
Green LED Range: 1.5 – 77,000 lm  1.5 – 77,000 lm
Blue LED Range: 0.50 – 23,000 lm  0.50 – 23,000 lm
Max Recommended Lamp Dimension: 7 x 7 in (18 x 18 cm  7 x 7 in (18 x 18 cm
Maximum Tubular Lamp Length: 34 in (86 cm)  34 in (60 cm)
Sphere Dimension: (W x D x H)  112.6 x 78.4 x 84.1 in  112.6 x 78.4 x 84.1 in

2.86 x 1.99 x 2.13 m 2.86 x 1.99 x 2.13 m
Spectrometer  CDS 1100  CDS 2100
Detector TE Cooled: 1044 x 64 CCD (back thinned)  1044 x 64 CCD (back thinned)
Spectral Range: 250-850 nm  350-1050 nm
Resolution: 1.5 FWHM  1.5 FWHM
Integration Time: 8 ms – 40 s  8 ms - 40 s
Cooling: 10 +/- 0.05 C  10 +/- 0.05 C
TE Temp Drift: +/- 1 C  +/- 1 C
Linearity:
+/- 0.5% +/- 0.5%
Wavelength Accuracy: <+/- 0.4 nm  <+/- 0.4 nm
Stray Light Broadband: <10-4 at 400nm w/ Ill A source  <10-4 at 400nm w/ Ill A source
Stray Light LED/Laser: <10-5 at 500nm w/633 nm laser  <10-5 at 500nm w/633 nm laser
Focal Length: 100 mm  100 mm
Optical Input: 600 mm, 3m long (SMA Connection)  600 mm, 3m long (SMA Connection)
Speed: 0.1 scans /sec  0.1 scans /sec
Dynamic Range: (single scan)
30000:1  30000:1
Spectral Sample Interval: 0.25nm  0.25nm
Mechanical Shutter: Yes  Yes
AD Converter: 16 bit  16 bit
PC Interface: USB 2.0 USB 2.0
Trigger: 11.3 lbs (5.04 kg)  11.3 lbs (5.04 kg)
Dimensions: (W x D x H) 8.3 x 13.0 x 3.5 in  8.3 x 13.0 x 3.5 in 

(21.1 x 32.9 x 8.9 cm 21.1 x 32.9 x 8.9 cm



Power Supply:
LPS 150-0268  LPS 150-0268
Power Requirements:  110./220 VAC, 50/60 Hz  110./220 VAC, 50/60 Hz
Current Stability: +/- 0.01%  +/- 0.01%
Current Rise Time: 20 +/- 5 seconds  20 +/- 5 seconds
Regulated Current: 2.679 A +/- 0.1%  2.679 A +/- 0.1%
Weight: 6.5 lbs. (2.9 kg)  6.5 lbs. (2.9 kg)
Dimension: (W x D x H) 8.3 x 10.5 x 3.5 in  8.3 x 10.5 x 3.5 in

21.1 x 26.7 x 8.9 cm 21.1 x 26.7 x 8.9 cm
Compliance: CE  CE



Optional Accessories

Sphere Photometer Temperature Probe, TP-100  AS-02637-100
Sphere Photometer Monitor and Probe, TPM-100  AS-02638-100
35W Absorption Correction Lamp, AUX-35  AS-02639-000



CSLMS 76 inch Sphere CSLMS 7611
CSLMS 7621
Choice Spectral Lamp Measurement System  AS-02481-600  AS-02481-700



System Includes:

Lamp Measurement Sphere, 76 inch AS-02481-000 AS-02481-000
CCD Array Spectrometer, CDS 1100 or 2100 AS-02746-100  AS-02746-200
Spectral Calibrated Lamp, SCL-1400 AS-01342-000  AS-01342-000
Lamp Power Supply, LPS-150-0268 AS-02656-268  AS-02656-268
MtrX-SPEC Spectral Light Measurement Software, required, sold separately LightMtrX LightMtrX
Operating System: Windows XP, VISTA and 7 Windows XP, VISTA and 7



System Properties and Performance




Sphere: LMS-7600  LMS-7600
Sphere Diameter: 76 in (1.93 m)  76 in (1.93 m)
Sphere Coating Reflectance: 98% 98%
Radiometric Range: 5,000 W (max)  5,000 W (max)
Photometric Range: (Illuminant A) 0.08 – 260,000 lm  0.08 – 260,000 lm
Red LED Range: 1.7 – 93,000 lm  1.7 – 93,000 lm
Green LED Range: 2.0 – 10,000 lm  2.0 – 10,000 lm
Blue LED Range: 0.70 – 32,000 lm  0.70 – 32,000 lm
Max Recommended Lamp Dimension: 8 x 8 in (21 x 21 cm)  8 x 8 in (21 x 21 cm)
Maximum Tubular Lamp Length: 52 in (1.3 m)  52 in (1.3 m)
Sphere Dimension: (W x D x H)  116.9 x 88.2 x 91.4 in  116.9 x 88.2 x 91.4 in

2.97 x 2.24 x 2.32 m 2.97 x 2.24 x 2.32 m



Spectrometer  CDS 1100  CDS 2100
Detector TE Cooled: 1044 x 64 CCD (back thinned)  1044 x 64 CCD (back thinned)
Spectral Range: 250-850 nm  350-1050 nm
Resolution: 1.5 FWHM  1.5 FWHM
Integration Time: 8 ms – 40 s  8 ms - 40 s
Cooling: 10 +/- 0.05 C  10 +/- 0.05 C
TE Temp Drift: +/- 1 C  +/- 1 C
Linearity: +/- 0.5% +/- 0.5%
Wavelength Accuracy: <+/- 0.4 nm  <+/- 0.4 nm
Stray Light Broadband: <10-4 at 400nm w/ Ill A source  <10-4 at 400nm w/ Ill A source
Stray Light LED/Laser: <10-5 at 500nm w/633 nm laser  <10-5 at 500nm w/633 nm laser
Focal Length: 100 mm  100 mm
Optical Input: 600 mm, 3m long (SMA Connection)  600 mm, 3m long (SMA Connection)
Speed: 0.1 scans /sec  0.1 scans /sec
Dynamic Range: (single scan)
30000:1  30000:1
Spectral Sample Interval: 0.25nm  0.25nm
Mechanical Shutter: Yes  Yes
AD Converter: 16 bit  16 bit
PC Interface: USB 2.0 USB 2.0
Trigger: 11.3 lbs (5.04 kg)  11.3 lbs (5.04 kg)
Dimensions: (W x D x H) 8.3 x 13.0 x 3.5 in  8.3 x 13.0 x 3.5 in 

(21.1 x 32.9 x 8.9 cm 21.1 x 32.9 x 8.9 cm



Power Supply LPS 150-0268  LPS 150-0268
Power Requirements: 110/220 VAC, 50/60 Hz  110/220 VAC, 50/60 Hz
Current Stability: +/- 0.01%  +/- 0.01%
Current Rise Time: 20 +/- 5 seconds  20 +/- 5 seconds
Regulated Current: 2.679 A +/- 0.1%  2.679 A +/- 0.1%
Weight: 6.5 lbs. (2.9 kg) 6.5 lbs. (2.9 kg)
Dimension: (W x D x H) 8.3 x 10.5 x 3.5 in  8.3 x 10.5 x 3.5 in

21.1 x 26.7 x 8.9 cm 21.1 x 26.7 x 8.9 cm
Compliance: CE  CE



Optional Accessories

Sphere Photometer Temperature Probe, TP-100  AS-02637-100
Sphere Photometer Monitor and Probe, TPM-100  AS-02638-100
35W Absorption Correction Lamp, AUX-35  AS-02639-000
Print PDF of this page