CSLMS Choice Spectral Lamp Measurement Systems
FEATURES:
- NIST Traceable Standards for In-house Recalibration
- Spectral Results in Milliseconds
- LightMtrX® Measurement Software
- Spectraflect® Interior
- CIE Recommended Geometry
MEASURE:
- Total Spectral Flux (Watts/nm)
- Total Radiant Flux (Watts)
- Total Luminous Flux (lumens)
- Color (CCT)
- Color Ellipses and Quadrangles
- Lamp Performance vs. Time
- Peak and Dominant Wavelength
- Spectral Purity
- Color Rendering Index (CRI)
- Chromaticity Coordinates
- FWHM
APPLICATIONS:
- LEDs
- Miniature Lamps
- LED Sourced Systems
Labsphere continues to set the pace in the industry with its CSLMS Spectral Lamp Measurement Systems, which provide total spectral flux solutions. Featuring our high-end spectrometers and LightMtrX® Software, combined with our light measurement spheres and lamp standards, CSLMS Spectral Lamp Measurement Systems are the optimum choice for spectral flux measurements. The heart of these systems is either the CDS 1100 or CDS 2100 Spectrometer coupled with Labsphere's application based software. The base design of these spectrometers is the proven Crossed Czerny-Turner spectrograph with a top-of-the-line thermal electrically cooled back thinned illuminated CCD detector designed for highly efficient stray-light rejection. Carrying over the best features of our industry proven spectrometers while addressing today's industries needs, these spectral engines include user activated integrated shutters for real-time dark correction and intuitive software modules for research, development and production.
Systems are available with sphere sizes ranging from 10 to 76 inches in diameter to accommodate various device types and sizes. The systems can be expanded to include an auxiliary lamp for the correction of absorption error to ensure accurate test results. National Institute of Standards and Technology (NIST) traceable total spectral flux standards enable simple in-house system calibration and verification. The CSLMS Spectral Lamp Measurement Systems are easily customized through a variety of interchangeable light measurement accessories. Download CSLMS Medium Datasheet
Download CSLMS Large Datasheet
LIGHT MEASUREMENT INTEGRATING SPHERE DESIGN
The CSLMS light measurement integrating spheres have a latch-free clamshell design for easy access to the device under test (DUT). The base portion admits additional cables for assembled fixtures while the external port provides for a unobstructed positioning of board mounted or heat-sinked devices for forward flux and partial flux measurements. A telescopic lamp mount can be repositioned with a quick twist for base up, base down or horizontal lamp positioning. Exchangeable baffles give optimal detector screening efficiency while quick connect internal and external electrical contacts allow for effortless substitution between devices under test.
The interiors of the integrating spheres are coated with Spectraflect® Diffuse Reflectance Coating which combines a 98% reflective surface with nearly perfect Lambertian reflectance. Both durable and highly stable, Spectraflect® provides consistent integration of light over the lifetime of your sphere.
EASY TO USE
All CSLMS Spectral Measurement Systems combine intuitive operating software with high-speed hardware to simplify complex measurements. The coupling of application specific software with a CCD-based spectrometer (wavelength ranges 250-850 nm or 350-1050), integrating sphere and cosine receiver makes it possible to collect total spectral flux, luminous flux, radiometric flux and colorimetric data in milliseconds.
OPERATING SOFTWARE
The Windows®-based LightMtrX-SPEC Software® guides users through testing, providing straightforward testing procedures and repeatable results to meet the needs of both new users and experienced researchers. DLL drivers are standard with the LightMtrX® platform, including examples written for today's most popular programming languages. When you are ready to increase your capacity, the integral design and user graphical interface make it easy to transition from research to production.
Software Functions and Features
- Menu Driven Operation
- User Calibration and Validation Processes
- Display, Log, and Store Results for Research
- Pass/Fail Testing for Production
- Temporal Plots for Life Performance
CHOOSE FROM:
CSLMS SPECTRAL LAMP MEASUREMENT SYSTEMS - Medium Systems 10 and 20 inch diameter integrating spheres to accommodate devices from 1 x1 inch (3 x 3 cm) to 2 x 2 inches (5 x 5 cm)
CSLMS SPECTRAL LAMP MEASUREMENT SYSTEMS - Large Systems 40, 65 and 76 inch diameter integrating spheres to accommodate large devices and arrays from 4 x 4 inches (10 x 10 cm) up to 8 x 8 inches (21 x 21 cm).
CSLMS SPECTRAL LAMP MEASUREMENT SYSTEMS - Medium Systems
Ordering Information and Specifications
| Description and Model |
CSLMS 1011 |
CSLMS 1021 |
| 10 inch Spectral Lamp Measurement System |
|
|
| with CDS 1100 or 2100 |
AS-02477-600 |
AS-02477-700 |
|
|
|
| System Includes: |
|
|
| Light Measurement Sphere, LMS 100 |
AS-02478-000 |
AS-02478-000 |
| Spectrally Calibrated Lamp, SCL-600 |
AS-01335-000 |
AS-01335-000 |
| Lamp Socket Assembly |
AS-02478-002 |
AS-02478-002 |
| Preset Power Supply, LPS-100-0260, 2.60 A, 35 W |
AS-02600-260 |
AS-02600-260 |
| CCD Array Spectrometer, CDS 1100 or CDS 2100 |
AS-02746-100 |
AS-02746-200 |
MtrX-SPEC Spectral Light Measurement Software, required, sold separately
|
Light MtrX |
Light MtrX |
|
|
|
| System Properties and Performance |
|
|
|
|
|
| Sphere Size: |
10 in (25 cm) |
10 in (25 cm) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
100 W (max) |
100 W (max) |
| Photometric Range: (Illuminant A) |
560 mlm – 12500 lm |
385 mlm – 8500 lm |
| Red LED Range: |
95 mlm – 2100 lm |
100 mlm – 2200 lm |
| Green LED Range: |
335 mlm – 7450 lm |
375 mlm – 8400 lm |
| Blue LED Range: |
140 mlm – 3050 lm |
145 mlm – 3100 lm |
| Spectral Range: |
350 - 850 nm |
350 - 1050 nm |
| Max Recommended DUT Dimension: |
1 x 1 in (3 x 3 cm) |
1 x 1 in (3 x 3 cm) |
| Sphere Weight: |
8 lbs (3.6 kg) |
8 lbs (3.6 kg) |
| Sphere Dimension: (W x D x H) |
16.7 x 11 9 x 15.5 in |
16.7 x 11 9 x 15.5 in |
|
42.4 x 30.2 x 39.4 cm |
42.4 x 30.2 x 39.4 cm |
|
|
|
| Spectrometer |
CDS 1100 |
CDS 2100 |
| Detector: |
1044 x 64 CCD (back thinned) |
1044 x 64 CCD (back thinned) |
| Spectral Range: CCD TE Cooled |
250-850 nm |
350-1050 nm |
| Resolution: |
1.5 FWHM |
1.5 FWHM |
| Integration Time: |
8 ms – 40 s |
8 ms - 40 s |
| Cooling: |
10 +/- 0.05 C |
10 +/- 0.05 C |
| TE Temp Drift: |
+/- 1 C |
+/- 1 C |
| Linearity: |
+/- 0.5% |
+/- 0.5% |
| Wavelength Accuracy: |
<+/- 0.4 nm |
<+/- 0.4 nm |
| Stray Light Broadband: |
<10-4 at 400nm w/ Ill A source |
<10-4 at 400nm w/ Ill A source |
| Stray Light LED/Laser: |
<10-5 at 500nm w/633 nm laser |
<10-5 at 500nm w/633 nm laser |
| Focal Length: |
100 mm |
100 mm |
| Optical Input: |
600 mm, 3m long (SMA Connection) |
600 mm, 3m long (SMA Connection) |
| Speed: |
0.1 scans /sec |
0.1 scans /sec |
| Dynamic Range: (single scan) |
30000:1 |
30000:1 |
| Spectral Sample Interval: |
0.25nm |
0.25nm |
| Mechanical Shutter: |
Yes |
Yes |
| AD Converter: |
16 bit |
16 bit |
| PC Interface: |
USB 2.0 |
USB 2.0 |
| Trigger : |
11.3 lbs (5.04 kg) |
11.3 lbs (5.04 kg) |
| Dimensions: (W x D x H): |
8.3 x 13.0 x 3.5 in |
8.3 x 13.0 x 3.5 in |
|
21.1 x 32.9 x 8.9 cm |
21.1 x 32.9 x 8.9 cm |
|
|
|
| Lamp Standard |
SCL-600 |
SCL-600 |
Power:
|
35 W |
35 W |
| Approximate Luminous Flux: |
450 lm |
450 lm |
| Rated Life: |
300 hrs |
300 hrs |
| Calibration: |
Spectral Flux (W/nm) |
Spectral Flux (W/nm) |
|
350 - 1050 nm |
350 - 1050 nm |
|
|
|
| Power Supply |
LPS-100-0260, 2.60 A, 35 W |
LPS-100-0260, 2.60 A, 35 W |
| Power Requirements: |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz |
| Current Stability: |
0.10% |
0.10% |
| Current Rise Time: |
20 s |
20 s |
| Regulated Current: |
2.60 A +/- 0.1% |
2.60 A +/- 0.1% |
| Weight: |
6.5 lbs (2.9 kg) |
6.5 lbs (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| Optional Accessories |
|
|
| Sphere Photometer Temperature Probe, TP-100 |
AS-02637-100 |
|
| Sphere Photometer Monitor and Probe, TPM-100 |
AS-02638-100 |
|
| 35W Absorption Correction Lamp, AUX-35 |
AS-02639-000 |
|
Ordering Information and Specifications
| Description |
CSLMS 2011 |
CSLMS 2021 |
| 20 inch Spectral Lamp Measurement System |
|
|
| with CDS 1100 or 2100 |
AS-02478-600 |
AS-02478-700 |
|
|
|
| System Includes: |
|
|
| Light Measurement Sphere, LMS 200 |
AS-02478-000 |
AS-02478-000 |
| Spectrally Calibrated Lamp, SCL-600 |
AS-01335-000 |
AS-01335-000 |
| Lamp Socket Assembly |
AS-02478-002 |
AS-02478-002 |
| Preset Power Supply, LPS-100-0260, 2.60 A, 35 W |
AS-02600-260 |
AS-02600-260 |
| CCD Array Spectrometer, CDS 1100 or CDS 2100 |
AS-02746-100 |
AS-02746-200 |
MtrX-SPEC Spectral Light Measurement Software, required, sold separately
|
Light MtrX |
Light MtrX |
|
|
|
| System Properties and Performance |
|
|
| Sphere Size: |
20 in (50 cm) |
20 in (50 cm) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
400 W (max) |
400 W (max) |
| Photometric Range: (Illuminant A) |
2.25 lm – 50000 lm |
1.55 lm – 34000 lm |
| Red LED Range: |
375 mlm – 8400 lm |
395 mlm – 8800 lm |
| Green LED Range: |
1.35 lm – 30000 lm |
1.50 lm – 33700 lm |
| Blue LED Range: |
550 mlm – 12000 lm |
570 mlm – 12700 lm |
| Spectral Range: |
350 - 850 nm |
350 - 1050 nm |
| Max Recommended DUT Dimension: |
2 x 2 in (5 x 5 cm) |
2 x 2 in (5 x 5 cm) |
| Sphere Weight: |
21 lbs (9.5 kg) |
21 lbs (9.5 kg) |
| Sphere Dimension: (W x D x H) |
28.5 x 23.7 x 29.4 in |
28.5 x 23.7 x 29.4 in |
|
72.4 x 60.2 x 74.7cm |
72.4 x 60.2 x 74.7cm |
|
|
|
| Spectrometer |
CDS 1100 |
CDS 2100 |
| Detector TE Cooled: |
1044 x 64 CCD (back thinned) |
1044 x 64 CCD (back thinned) |
| Spectral Range: |
250-850 nm |
350-1050 nm |
| Resolution: |
1.5 FWHM |
1.5 FWHM |
| Integration Time: |
8 ms – 40 s |
8 ms - 40 s |
| Cooling: |
10 +/- 0.05 C |
10 +/- 0.05 C |
| TE Temp Drift: |
+/- 1 C |
+/- 1 C |
Linearity:
|
+/- 0.5% |
+/- 0.5% |
| Wavelength Accuracy: |
<+/- 0.4 nm |
<+/- 0.4 nm |
| Stray Light Broadband: |
<10-4 at 400nm w/ Ill A source |
<10-4 at 400nm w/ Ill A source |
| Stray Light LED/Laser: |
<10-5 at 500nm w/633 nm laser |
<10-5 at 500nm w/633 nm laser |
| Focal Length: |
100 mm |
100 mm |
| Optical Input: |
600 mm, 3m long (SMA Connection) |
600 mm, 3m long (SMA Connection) |
| Speed: |
0.1 scans /sec |
0.1 scans /sec |
Dynamic Range: (single scan)
|
30000:1 |
30000:1 |
| Spectral Sample Interval: |
0.25nm |
0.25nm |
| Mechanical Shutter: |
Yes |
Yes |
| AD Converter: |
16 bit |
16 bit |
| PC Interface: |
USB 2.0 |
USB 2.0 |
| Trigger: |
11.3 lbs (5.04 kg) |
11.3 lbs (5.04 kg) |
| Dimensions: (W x D x H) |
8.3 x 13.0 x 3.5 in |
8.3 x 13.0 x 3.5 in |
|
(21.1 x 32.9 x 8.9 cm |
21.1 x 32.9 x 8.9 cm |
|
|
|
| Lamp Standard |
SCL-600 |
SCL-600 |
| Power: |
35 W |
35 W |
| Approximate Luminous Flux: |
450 lm |
450 lm |
Rated Life:
|
300 hrs |
300 hrs |
| Calibration: |
Spectral Flux (W/nm) |
Spectral Flux (W/nm) |
|
350 - 1050 nm |
350 - 1050 nm |
|
|
|
| Power Supply |
LPS-100-0260, 2.60 A, 35 W |
LPS-100-0260, 2.60 A, 35 W |
| Power Requirements: |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz |
| Current Stability: |
0.10% |
0.10% |
| Current Rise Time: |
20 s |
20 s |
| Regulated Current: |
2.60 A +/- 0.1% |
2.60 A +/- 0.1% |
| Weight: |
6.5 lbs (2.9 kg) |
6.5 lbs (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| Optional Accessories |
|
|
| Sphere Photometer Temperature Probe, TP-100 |
AS-02637-100 |
|
| Sphere Photometer Monitor and Probe, TPM-100 |
AS-02638-100 |
|
| 35W Absorption Correction Lamp, AUX-35 |
AS-02639-000 |
|
CLSMS-SPECTRAL LAMP MEASUREMENT SYSTEMS – Large Systems
Ordering information and Specifications
| CSLMS LED - 40 inch Sphere |
CSLMS 4011
|
CSLMS 4021 |
| Choice Spectral Lamp Measurement System |
AS-02479-600 |
AS-02479-700 |
| System Includes: |
|
|
| Lamp Measurement Sphere, 40 inch |
AS-02479-000 |
AS-02479-000 |
| CCD Array Spectrometer, CDS 1100 or 2100 |
AS-02746-100 |
AS-02746-200 |
| Spectral Calibrated Lamp, SCL-1400 |
AS-01342-000 |
AS-01342-000 |
| Lamp Power Supply, LPS-150-0268 |
AS-02656-268 |
AS-02656-268 |
| MtrX-SPEC Spectral Light Measurement Software, required, sold separately |
Light MtrX |
Light MtrX |
| Operating System: |
Windows XP, VISTA and 7 |
Windows XP, VISTA and 7 |
|
|
|
| System Properties and Performance |
|
|
| Sphere: |
LMS-400 |
LMS-400 |
| Sphere Diameter: |
40 in (1.02 m) |
40 in (1.02 m) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
1,500 W (max) |
1,500 W (max) |
Photometric Range: (Illuminant A)
|
2 – 72,500 lm |
2 – 72,500 lm |
| Red LED Range: |
0.62 – 26,000 lm |
0.62 – 26,000 lm |
| Green LED Range: |
0.60 – 28,500 lm |
0.60 – 28,500 lm |
| Blue LED Range: |
0.25 – 8,900 lm |
0.25 – 8,900 lm |
| Max Recommended Lamp Dimension: |
4 x 4 in (10 x 10 cm) |
4 x 4 in (10 x 10 cm) |
| Maximum Tubular Lamp Length: |
24 in (60 cm) |
24 in (60 cm) |
Sphere Dimension: (W x D x H)
|
48.9 x 42.3 x 68.5 in |
48.9 x 42.3 x 68.5 in |
|
(1.24 x 1.07 x 1.74 m) |
(1.24 x 1.07 x 1.74 m) |
|
|
|
| Spectrometer |
CDS 1100 |
CDS 2100 |
| Detector TE Cooled: |
1044 x 64 CCD (back thinned) |
1044 x 64 CCD (back thinned) |
| Spectral Range: |
250-850 nm |
350-1050 nm |
| Resolution: |
1.5 FWHM |
1.5 FWHM |
| Integration Time: |
8 ms – 40 s |
8 ms - 40 s |
| Cooling: |
10 +/- 0.05 C |
10 +/- 0.05 C |
| TE Temp Drift: |
+/- 1 C |
+/- 1 C |
Linearity:
|
+/- 0.5% |
+/- 0.5% |
| Wavelength Accuracy: |
<+/- 0.4 nm |
<+/- 0.4 nm |
| Stray Light Broadband: |
<10-4 at 400nm w/ Ill A source |
<10-4 at 400nm w/ Ill A source |
| Stray Light LED/Laser: |
<10-5 at 500nm w/633 nm laser |
<10-5 at 500nm w/633 nm laser |
| Focal Length: |
100 mm |
100 mm |
| Optical Input: |
600 mm, 3m long (SMA Connection) |
600 mm, 3m long (SMA Connection) |
| Speed: |
0.1 scans /sec |
0.1 scans /sec |
Dynamic Range: (single scan)
|
30000:1 |
30000:1 |
| Spectral Sample Interval: |
0.25nm |
0.25nm |
| Mechanical Shutter: |
Yes |
Yes |
| AD Converter: |
16 bit |
16 bit |
| PC Interface: |
USB 2.0 |
USB 2.0 |
| Trigger: |
11.3 lbs (5.04 kg) |
11.3 lbs (5.04 kg) |
| Dimensions: (W x D x H) |
8.3 x 13.0 x 3.5 in |
8.3 x 13.0 x 3.5 in |
|
(21.1 x 32.9 x 8.9 cm |
21.1 x 32.9 x 8.9 cm |
|
|
|
| Power Supply |
LPS 150-0268 |
LPS 150-0268 |
| Power Requirements: |
110./220 VAC, 50/60 Hz |
110./220 VAC, 50/60 Hz |
| Current Stability: |
+/- 0.01% |
+/- 0.01% |
| Current Rise Time: |
20 +/- 5 seconds |
20 +/- 5 seconds |
| Regulated Current: |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
| Weight: |
6.5 lbs. (2.9 kg) |
6.5 lbs. (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| Optional Accessories |
|
|
| Sphere Photometer Temperature Probe, TP-100 |
AS-02637-100 |
|
| Sphere Photometer Monitor and Probe, TPM-100 |
AS-02638-100 |
|
| 35W Absorption Correction Lamp, AUX-35 |
AS-02639-000 |
|
SPECIFICATIONS AND ORDERING INFORMATION
| CSLMS 65 inch Sphere |
CSLMS 6511
|
CSLMS 6521 |
| Choice Spectral Lamp Measurement System |
AS-02480-600 |
AS-02480700 |
| System Includes: |
|
|
| Lamp Measurement Sphere, 65 inch |
AS-02480-000 |
AS-02480-000 |
| CCD Array Spectrometer, CDS 1100 or 2100 |
AS-02746-100 |
AS-02746-200 |
| Spectral Calibrated Lamp, SCL-1400 |
AS-01342-000 |
AS-01342-000 |
| Lamp Power Supply, LPS-150-0268 |
AS-02656-268 |
AS-02656-268 |
| MtrX-SPEC Spectral Light Measurement Software, required, sold separately |
LightMtrX |
LightMtrX |
| Operating System: |
Windows XP, VISTA and 7 |
Windows XP, VISTA and 7 |
|
|
|
| System Properties and Performance |
|
|
| Sphere: |
LMS-6500 |
LMS-6500 |
| Sphere Diameter: |
65 in (1.65 m) |
65 in (1.65 m) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
4,000 W (max) |
4,000 W (max) |
| Photometric Range: (Illuminant A) |
6 – 200,000 lm |
6 – 200,000 lm |
| Red LED Range: |
1.2 – 68,000 lm |
1.2 – 68,000 lm |
| Green LED Range: |
1.5 – 77,000 lm |
1.5 – 77,000 lm |
| Blue LED Range: |
0.50 – 23,000 lm |
0.50 – 23,000 lm |
| Max Recommended Lamp Dimension: |
7 x 7 in (18 x 18 cm |
7 x 7 in (18 x 18 cm |
| Maximum Tubular Lamp Length: |
34 in (86 cm) |
34 in (60 cm) |
| Sphere Dimension: (W x D x H) |
112.6 x 78.4 x 84.1 in |
112.6 x 78.4 x 84.1 in |
|
2.86 x 1.99 x 2.13 m |
2.86 x 1.99 x 2.13 m |
| Spectrometer |
CDS 1100 |
CDS 2100 |
| Detector TE Cooled: |
1044 x 64 CCD (back thinned) |
1044 x 64 CCD (back thinned) |
| Spectral Range: |
250-850 nm |
350-1050 nm |
| Resolution: |
1.5 FWHM |
1.5 FWHM |
| Integration Time: |
8 ms – 40 s |
8 ms - 40 s |
| Cooling: |
10 +/- 0.05 C |
10 +/- 0.05 C |
| TE Temp Drift: |
+/- 1 C |
+/- 1 C |
Linearity:
|
+/- 0.5% |
+/- 0.5% |
| Wavelength Accuracy: |
<+/- 0.4 nm |
<+/- 0.4 nm |
| Stray Light Broadband: |
<10-4 at 400nm w/ Ill A source |
<10-4 at 400nm w/ Ill A source |
| Stray Light LED/Laser: |
<10-5 at 500nm w/633 nm laser |
<10-5 at 500nm w/633 nm laser |
| Focal Length: |
100 mm |
100 mm |
| Optical Input: |
600 mm, 3m long (SMA Connection) |
600 mm, 3m long (SMA Connection) |
| Speed: |
0.1 scans /sec |
0.1 scans /sec |
Dynamic Range: (single scan)
|
30000:1 |
30000:1 |
| Spectral Sample Interval: |
0.25nm |
0.25nm |
| Mechanical Shutter: |
Yes |
Yes |
| AD Converter: |
16 bit |
16 bit |
| PC Interface: |
USB 2.0 |
USB 2.0 |
| Trigger: |
11.3 lbs (5.04 kg) |
11.3 lbs (5.04 kg) |
| Dimensions: (W x D x H) |
8.3 x 13.0 x 3.5 in |
8.3 x 13.0 x 3.5 in |
|
(21.1 x 32.9 x 8.9 cm |
21.1 x 32.9 x 8.9 cm |
|
|
|
Power Supply:
|
LPS 150-0268 |
LPS 150-0268 |
| Power Requirements: |
110./220 VAC, 50/60 Hz |
110./220 VAC, 50/60 Hz |
| Current Stability: |
+/- 0.01% |
+/- 0.01% |
| Current Rise Time: |
20 +/- 5 seconds |
20 +/- 5 seconds |
| Regulated Current: |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
| Weight: |
6.5 lbs. (2.9 kg) |
6.5 lbs. (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| Optional Accessories |
|
|
| Sphere Photometer Temperature Probe, TP-100 |
AS-02637-100 |
|
| Sphere Photometer Monitor and Probe, TPM-100 |
AS-02638-100 |
|
| 35W Absorption Correction Lamp, AUX-35 |
AS-02639-000 |
|
|
|
|
| CSLMS 76 inch Sphere |
CSLMS 7611
|
CSLMS 7621 |
| Choice Spectral Lamp Measurement System |
AS-02481-600 |
AS-02481-700 |
|
|
|
| System Includes: |
|
|
| Lamp Measurement Sphere, 76 inch |
AS-02481-000 |
AS-02481-000 |
| CCD Array Spectrometer, CDS 1100 or 2100 |
AS-02746-100 |
AS-02746-200 |
| Spectral Calibrated Lamp, SCL-1400 |
AS-01342-000 |
AS-01342-000 |
| Lamp Power Supply, LPS-150-0268 |
AS-02656-268 |
AS-02656-268 |
| MtrX-SPEC Spectral Light Measurement Software, required, sold separately |
LightMtrX |
LightMtrX |
| Operating System: |
Windows XP, VISTA and 7 |
Windows XP, VISTA and 7 |
|
|
|
| System Properties and Performance |
|
|
|
|
|
| Sphere: |
LMS-7600 |
LMS-7600 |
| Sphere Diameter: |
76 in (1.93 m) |
76 in (1.93 m) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
5,000 W (max) |
5,000 W (max) |
| Photometric Range: (Illuminant A) |
0.08 – 260,000 lm |
0.08 – 260,000 lm |
| Red LED Range: |
1.7 – 93,000 lm |
1.7 – 93,000 lm |
| Green LED Range: |
2.0 – 10,000 lm |
2.0 – 10,000 lm |
| Blue LED Range: |
0.70 – 32,000 lm |
0.70 – 32,000 lm |
| Max Recommended Lamp Dimension: |
8 x 8 in (21 x 21 cm) |
8 x 8 in (21 x 21 cm) |
| Maximum Tubular Lamp Length: |
52 in (1.3 m) |
52 in (1.3 m) |
| Sphere Dimension: (W x D x H) |
116.9 x 88.2 x 91.4 in |
116.9 x 88.2 x 91.4 in |
|
2.97 x 2.24 x 2.32 m |
2.97 x 2.24 x 2.32 m |
|
|
|
| Spectrometer |
CDS 1100 |
CDS 2100 |
| Detector TE Cooled: |
1044 x 64 CCD (back thinned) |
1044 x 64 CCD (back thinned) |
| Spectral Range: |
250-850 nm |
350-1050 nm |
| Resolution: |
1.5 FWHM |
1.5 FWHM |
| Integration Time: |
8 ms – 40 s |
8 ms - 40 s |
| Cooling: |
10 +/- 0.05 C |
10 +/- 0.05 C |
| TE Temp Drift: |
+/- 1 C |
+/- 1 C |
| Linearity: |
+/- 0.5% |
+/- 0.5% |
| Wavelength Accuracy: |
<+/- 0.4 nm |
<+/- 0.4 nm |
| Stray Light Broadband: |
<10-4 at 400nm w/ Ill A source |
<10-4 at 400nm w/ Ill A source |
| Stray Light LED/Laser: |
<10-5 at 500nm w/633 nm laser |
<10-5 at 500nm w/633 nm laser |
| Focal Length: |
100 mm |
100 mm |
| Optical Input: |
600 mm, 3m long (SMA Connection) |
600 mm, 3m long (SMA Connection) |
| Speed: |
0.1 scans /sec |
0.1 scans /sec |
Dynamic Range: (single scan)
|
30000:1 |
30000:1 |
| Spectral Sample Interval: |
0.25nm |
0.25nm |
| Mechanical Shutter: |
Yes |
Yes |
| AD Converter: |
16 bit |
16 bit |
| PC Interface: |
USB 2.0 |
USB 2.0 |
| Trigger: |
11.3 lbs (5.04 kg) |
11.3 lbs (5.04 kg) |
| Dimensions: (W x D x H) |
8.3 x 13.0 x 3.5 in |
8.3 x 13.0 x 3.5 in |
|
(21.1 x 32.9 x 8.9 cm |
21.1 x 32.9 x 8.9 cm |
|
|
|
| Power Supply |
LPS 150-0268 |
LPS 150-0268 |
| Power Requirements: |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz |
| Current Stability: |
+/- 0.01% |
+/- 0.01% |
| Current Rise Time: |
20 +/- 5 seconds |
20 +/- 5 seconds |
| Regulated Current: |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
| Weight: |
6.5 lbs. (2.9 kg) |
6.5 lbs. (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| Optional Accessories |
|
|
| Sphere Photometer Temperature Probe, TP-100 |
AS-02637-100 |
|
| Sphere Photometer Monitor and Probe, TPM-100 |
AS-02638-100 |
|
| 35W Absorption Correction Lamp, AUX-35 |
AS-02639-000 |
|
|
|
Print PDF of this page



|
|