CSLMS LED Choice Total Spectral Flux LED Measurement Systems
FEATURES:
- NIST Traceable Standards for In-house Recalibration
- Spectral Results in Milliseconds
- LightMtrX Measurement Software
- Spectraflect® Interior
- CIE Recommended Geometry
MEASURE:
- Total Spectral Flux
- Luminous Flux
- Radiant Flux
- Chromaticity
- CCT
- CRI
- Peak Wavelength
- Dominant Wavelength
APPLICATIONS:
- LEDs
- Miniature Lamps
- LED Sourced Systems
- Large-area LED Arrays
The CSLMS LED Series Measurement Systems are affordably priced and easily customized through a variety of interchangeable light measurement accessories. National Institute of Standards and Technology (NIST) traceable total spectral flux standards enable simple in-house system calibration and verification. Systems are available with sphere sizes ranging from 10 to 76-inches in diameter to accommodate various device types and sizes. The systems can be expanded to include an auxiliary lamp for the correction of absorption error to ensure accurate test results.
Download Guide
Download CSLMS LED Medium Datasheet
Download CSLMS LED Large Datasheet
LIGHT MEASUREMENT INTEGRATING SPHERE DESIGN
The CSLMS LED light measurement integrating spheres have a latch-free clamshell design for easy access to the device under test (DUT). The base portion admits additional cables for assembled fixtures while the external port provides for a unobstructed positioning of board mounted or heat-sinked devices for forward flux and partial flux measurements. A telescopic lamp mount can be repositioned with a quick twist for base up, base down or horizontal lamp positioning. Exchangeable baffles give optimal detector screening efficiency while quick connect internal and external electrical contacts allow for effortless substitution between devices under test.
The interiors of the integrating spheres are coated with Spectraflect® Diffuse Reflectance Coating which combines a 98% reflective surface with nearly perfect Lambertian reflectance. Both durable and highly stable, this coating provides consistent integration of light over the lifetime of your sphere.
EASY TO USE
All CSLMS LED Measurement Systems combine intuitive operating software with high-speed hardware to simplify complex measurements. The coupling of application specific software with a CCD-based spectrometer (wavelength ranges 200 - 850 nm or 350 - 1000), integrating sphere and cosine receiver makes it possible to collect total spectral flux, luminous flux, radiometric flux, and colorimetric data in milliseconds.
OPERATING SOFTWARE
The Windows®-based LightMtrX-SPEC software® guides users through testing, providing straightforward testing procedures and repeatable results to meet the needs of both new users and experienced researchers. DLL drivers are standard with the LightMtrX® platform, including examples written for today's most popular programming languages. When you are ready to increase your capacity, the integral design and user graphical interface make it easy to transition from research to production.
Software Functions and Features
- Menu Driven Operation
- User Calibration and Validation Processes
- Display, Log, and Store Results for Research
- Pass/Fail Testing for Production
- Temporal Plots for Life Performance
CHOOSE FROM:
CSLMS SPECTRAL LED MEASUREMENT SYSTEMS - Medium Systems 10 and 20 inch integrating spheres to accommodate devices from 1 x1 inch (3 x 3 cm) to 2 x 2 inches (5 x 5 cm)
CSLMS SPECTRAL LED MEASUREMENT SYSTEMS - Large Systems
40, 65 and 76 inch diameter integrating spheres to accommodate large devices and arrays from 4 x 4 inches (10 x 10 cm) up to 8 x 8 inches (21 x 21 cm).
CSLMS SPECTRAL LED MEASUREMENT SYSTEMS - Medium Systems
Ordering Information and Specifications
| Description and Model |
CSLMS LED 1060
|
CSLMS LED 1061 |
| 10 inch Spectral Flux Measurement System |
|
|
| with CDS 600 or 610 |
AS-02477-600 |
AS-02477-700 |
|
|
|
| System Includes: |
|
|
| Light Measurement Sphere, LMS 100 |
AS-02478-000 |
AS-02478-000 |
| Spectrally Calibrated Lamp, SCL-600 |
AS-01335-000 |
AS-01335-000 |
| Lamp Socket Assembly |
AS-02478-002 |
AS-02478-002 |
| Preset Power Supply, LPS-100-0260, 2.60 A, 35 W |
AS-02600-260 |
AS-02600-260 |
CCD Array Spectrometer, CDS 600 or CDS 610
|
AS-02767-000 |
AS-02767-100 |
|
|
|
| Software required, sold separately |
|
|
| MtrX-SPEC Spectral Light Measurement Software® |
LightMtrX® |
LightMtrX® |
|
|
|
| System Properties and Performance |
|
|
Light Measurement Sphere
|
LMS 100
|
LMS 100
|
| Sphere Size: |
10 in (25 cm) |
10 in (25 cm) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
100 W (max) |
100 W (max) |
| Photometric Range: (Illuminant A) |
0.4 – 13,000 lm |
0.4 – 13,000 lm
|
| Red LED Range: |
0.06 – 4,600 lm |
0.06 – 4,600 lm |
| Green LED Range: |
0.12 – 5,700 lm |
0.12 – 5,700 lm |
| Blue LED Range: |
0.04 – 1,900 lm |
0.04 – 1,900 lm |
| Max Recommended DUT Dimension: |
1 x 1 in (3 x 3 cm) |
1 x 1 in (3 x 3 cm) |
| Sphere Weight: |
8 lbs (3.6 kg) |
8 lbs (3.6 kg) |
| Sphere Dimension: (W x D x H) |
16.7 x 11 9 x 15.5 in |
16.7 x 11 9 x 15.5 in |
|
42.4 x 30.2 x 39.4 cm |
42.4 x 30.2 x 39.4 cm |
|
|
|
| Spectrometer |
CDS 600
|
CDS 610 |
| Dimensions: |
89.1 mm x 63.3 mm 34.4 mm
|
89.1 mm x 63.3 mm 34.4 mm |
Detector Range:
|
200 - 1100 nm |
350 - 1000 nm |
| Pixels: |
2048 pixels
|
2048 pixels |
| Pixel Size: |
14 µm x 200 mm
|
14 µm x 200 mm |
| Pixel Well Depth: |
~62,500 electrons
|
~62,500 electrons |
| TE Temp Drift: |
+/- 1 C |
+/- 1 C |
| Sensitivity: |
75 photons/count at 400 nm; 41 photons/count at 600 nm
|
75 photons/count at 400 nm; 41 photons/count at 600 nm |
| Focal Length: |
42 mm input; 68 mm output
|
42 mm input; 68 mm output |
| Entrance Aperture: |
100 µm
|
100 µm
|
| Wavelength Range: |
200 - 850 nm
|
350 - 1000 nm
|
| Signal-to-Noise Ratio: |
250:1 (at full signal)
|
250:1 (at full signal) |
| A/D Resolution: |
16 bit
|
16 bit
|
| Dynamic Range: |
2 x 10^8 (system)
|
2 x 10^8 (system) |
| Integration Time: |
8 ms to 30 seconds
|
8 ms to 30 seconds |
| Stray Light: |
<0.05% at 600 nm; <0.10% at 435 nm
|
<0.05% at 600 nm; <0.10% at 435 nm |
| Correct Linearity: |
>99.8%
|
>99.8% |
|
|
|
| Lamp Standard |
SCL-600 |
SCL-600 |
Power:
|
35 W
|
35 W |
| Approximate Luminous Flux: |
450 lm |
450 lm |
| Rated Life: |
300 hrs |
300 hrs |
| Calibration: |
Spectral Flux (W/nm) |
Spectral Flux (W/nm) |
|
350 - 1050 nm |
350 - 1050 nm |
|
|
|
| Power Supply: |
LPS-100-0260, 2.60 A, 35 W |
LPS-100-0260, 2.60 A, 35 W |
| Power Requirements: |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz |
| Current Stability: |
0.10% |
0.10% |
| Current Rise Time: |
20 s |
20 s |
| Regulated Current: |
2.60 A +/- 0.1% |
2.60 A +/- 0.1% |
| Weight: |
6.5 lbs (2.9 kg) |
6.5 lbs (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
Ordering Information and Specifications
| Description |
CSLMS LED 2011 |
CSLMS LED 2021 |
| 20 inch Spectral Flux Measurement System |
|
|
with CDS 600 or 610
|
AS-02478-800 |
AS-02478-900 |
|
|
|
| System Includes: |
|
|
| Light Measurement Sphere, LMS 200 |
AS-02478-000 |
AS-02478-000 |
| Spectrally Calibrated Lamp, SCL-600 |
AS-01335-000 |
AS-01335-000 |
| Lamp Socket Assembly |
AS-02478-002 |
AS-02478-002 |
| Preset Power Supply, LPS-100-0260, 2.60 A, 35 W |
AS-02600-260 |
AS-02600-260 |
CCD Array Spectrometer, CDS 600 or CDS 610
|
AS-02767-000 |
AS-02767-100 |
|
|
|
| Operating Software required, sold separately |
|
|
| MtrX-SPEC Spectral Light Measurement Software® |
LightMtrX® |
LightMtrX® |
|
|
|
| System Properties and Performance |
|
|
Light Measurement Sphere
|
LMS 200
|
LMS 200
|
| Sphere Size: |
20 in (50 cm) |
20 in (50 cm) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
400 W (max) |
400 W (max) |
Photometric Range: (Illuminant A)
|
2.25 lm – 50000 lm |
1.55 lm – 34000 lm |
| Red LED Range: |
375 mlm – 8400 lm |
395 mlm – 8800 lm |
| Green LED Range: |
1.35 lm – 30000 lm |
1.50 lm – 33700 lm |
| Blue LED Range: |
550 mlm – 12000 lm |
570 mlm – 12700 lm |
| Spectral Range: |
350 - 850 nm |
350 - 1050 nm |
| Max Recommended DUT Dimension: |
2 x 2 in (5 x 5 cm) |
2 x 2 in (5 x 5 cm) |
| Sphere Weight: |
21 lbs (9.5 kg) |
21 lbs (9.5 kg) |
| Sphere Dimension: (W x D x H) |
28.5 x 23.7 x 29.4 in |
28.5 x 23.7 x 29.4 in |
|
72.4 x 60.2 x 74.7cm |
72.4 x 60.2 x 74.7cm |
|
|
|
| Spectrometer |
CDS 600
|
CDS 610 |
| Dimensions: |
89.1 mm x 63.3 mm 34.4 mm
|
89.1 mm x 63.3 mm 34.4 mm |
Detector Range:
|
200 - 1100 nm |
350 - 1000 nm |
| Pixels: |
2048 pixels
|
2048 pixels |
| Pixel Size: |
14 µm x 200 mm
|
14 µm x 200 mm |
| Pixel Well Depth: |
~62,500 electrons
|
~62,500 electrons |
| TE Temp Drift: |
+/- 1 C |
+/- 1 C |
| Sensitivity: |
75 photons/count at 400 nm; 41 photons/count at 600 nm
|
75 photons/count at 400 nm; 41 photons/count at 600 nm |
| Focal Length: |
42 mm input; 68 mm output
|
42 mm input; 68 mm output |
| Entrance Aperture: |
100 µm
|
100 µm
|
| Wavelength Range: |
200 - 850 nm
|
350 - 1000 nm
|
| Signal-to-Noise Ratio: |
250:1 (at full signal)
|
250:1 (at full signal) |
| A/D Resolution: |
16 bit
|
16 bit
|
| Dynamic Range: |
2 x 10^8 (system)
|
2 x 10^8 (system) |
| Integration Time: |
8 ms to 30 seconds
|
8 ms to 30 seconds |
| Stray Light: |
<0.05% at 600 nm; <0.10% at 435 nm
|
<0.05% at 600 nm; <0.10% at 435 nm |
| Correct Linearity: |
>99.8%
|
>99.8% |
|
|
|
| Lamp Standard |
SCL-600 |
SCL-600 |
| Power: |
35 W |
35 W |
| Approximate Luminous Flux: |
450 lm |
450 lm |
Rated Life:
|
300 hrs
|
300 hrs |
| Calibration: |
Spectral Flux (W/nm) |
Spectral Flux (W/nm) |
|
350 - 1050 nm |
350 - 1050 nm |
|
|
|
| Power Supply: |
LPS-100-0260, 2.60 A, 35 W |
LPS-100-0260, 2.60 A, 35 W |
| Power Requirements: |
110/220 VAC, 50/60 Hz |
110/220 VAC, 50/60 Hz |
| Current Stability: |
0.10% |
0.10% |
| Current Rise Time: |
20 s |
20 s |
| Regulated Current: |
2.60 A +/- 0.1% |
2.60 A +/- 0.1% |
| Weight: |
6.5 lbs (2.9 kg) |
6.5 lbs (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
CLSMS-SPECTRAL LED MEASUREMENT SYSTEMS – Large Systems
Ordering Information and Specifications
| CSLMS LED - 40 inch Sphere |
CSLMS LED 4060 |
CSLMS LED 4061 |
| Choice Spectral Light Measurement System |
AS-02479-800 |
AS-02479-900 |
| System Includes: |
|
|
| Lamp Measurement Sphere, 40 inch |
AS-02479-000 |
AS-02479-000 |
| CCD Spectrometer, CDS 600 or 610 |
AS-02767-000 |
AS-02767-100 |
| Spectral Calibrated Lamp, SCL-1400 |
AS-01342-000 |
AS-01342-000 |
| Lamp Power Supply, LPS-150-0268 |
AS-02656-268 |
AS-02656-268 |
|
|
|
| Software required, sold separately |
|
|
| MtrX-SPEC Spectral Light Measurement Software® |
LightMtrX® |
LightMtrX® |
|
|
|
| System Properties and Performance |
|
|
| Light Measurement Sphere: |
LMS-400 |
LMS-400 |
| Sphere Diameter: |
40 in (1.02 m) |
40 in (1.02 m) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
1,500 W (max) |
1,500 W (max) |
Photometric Range: (Illuminant A)
|
2 – 72,500 lm |
2 – 72,500 lm |
| Red LED Range: |
0.62 – 26,000 lm |
0.62 – 26,000 lm |
| Green LED Range: |
0.60 – 28,500 lm |
0.60 – 28,500 lm |
| Blue LED Range: |
0.25 – 8,900 lm |
0.25 – 8,900 lm |
| Max Recommended Lamp Dimension: |
4 x 4 in (10 x 10 cm) |
4 x 4 in (10 x 10 cm) |
| Maximum Tubular Lamp Length: |
24 in (60 cm) |
24 in (60 cm) |
Sphere Dimension: (W x D x H)
|
48.9 x 42.3 x 68.5 in |
48.9 x 42.3 x 68.5 in |
|
(1.24 x 1.07 x 1.74 m) |
(1.24 x 1.07 x 1.74 m) |
|
|
|
| Spectrometer |
CDS 600 |
CDS 610 |
| Dimensions: |
89.1 mm x 63.3 mm x 34.4 mm |
89.1 mm x 63.3 mm x 34.4 mm |
| Pixels: |
2048 pixels |
2048 pixels |
| Pixel Size: |
14 µm x 200 µm |
14 µm x 200 µm |
| Pixel Well Depth: |
~62,500 electrons |
~62,500 electrons |
| Sensitivity: |
75 photons/ |
75 photons/ |
|
count at 400 nm; |
count at 400 nm; |
|
41 photons/ |
41 photons/ |
|
count at 600 nm |
count at 600 nm |
| Focal Length: |
42 mm input; |
42 mm input; |
|
68 mm output |
68 mm output |
| Entrance Aperture: |
100 µm |
100 µm |
| Wavelength Range: |
200 - 850 nm |
350 - 1000 nm |
| Signal-to-Noise Ratio: |
250:1 (at full signal) |
250:1 (at full signal) |
| A/D Resolution: |
16 bit |
16 bit |
| Dynamic Range: |
2 x 10^8 (system) |
2 x 10^8 (system) |
| Integration Time: |
8 ms to 30 seconds |
8 ms to 30 seconds |
| Stray Light: |
<0.05% at 600 nm; |
<0.05% at 600 nm; |
|
<0.10% at 435 nm |
<0.10% at 435 nm |
| Corrected Linearity: |
>99.8% |
>99.8% |
|
|
|
| Power Supply |
LPS 150-0268 |
LPS 150-0268 |
| Power Requirements: |
110./220 VAC, 50/60 Hz |
110./220 VAC, 50/60 Hz |
| Current Stability: |
+/- 0.01% |
+/- 0.01% |
| Current Rise Time: |
20 +/- 5 seconds |
20 +/- 5 seconds |
| Regulated Current: |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
| Weight: |
6.5 lbs. (2.9 kg) |
6.5 lbs. (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| CSLMS LED 65 inch Sphere |
CSLMS LED 6560 |
CSLMS LED 6561 |
| Choice Spectral Light Measurement System |
AS-02480-800 |
AS-02480-900 |
| System Includes: |
|
|
| Lamp Measurement Sphere, 65 inch |
AS-02480-000 |
AS-02480-000 |
| CCD Spectrometer, CDS 600 or 610 |
AS-02767-000 |
AS-02767-100 |
| Spectral Calibrated Lamp, SCL-1400 |
AS-01342-000 |
AS-01342-000 |
| Lamp Power Supply, LPS-150-0268 |
AS-02656-268 |
AS-02656-268 |
|
|
|
| Software required, sold separately |
|
|
| MtrX-SPEC Spectral Light Measurement Software® |
Light MtrX® |
Light MtrX® |
|
|
|
| System Properties and Performance |
|
|
| Light Measurement Sphere: |
LMS-6500 |
LMS-6500 |
| Sphere Diameter: |
65 in (1.65 m) |
65 in (1.65 m) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
4,000 W (max) |
4,000 W (max) |
| Photometric Range: (Illuminant A) |
6 – 200,000 lm |
6 – 200,000 lm |
| Red LED Range: |
1.2 – 68,000 lm |
1.2 – 68,000 lm |
| Green LED Range: |
1.5 – 77,000 lm |
1.5 – 77,000 lm |
| Blue LED Range: |
0.50 – 23,000 lm |
0.50 – 23,000 lm |
| Max Recommended Lamp Dimension: |
7 x 7 in (18 x 18 cm |
7 x 7 in (18 x 18 cm |
| Maximum Tubular Lamp Length: |
34 in (86 cm) |
34 in (60 cm) |
| Sphere Dimension: (W x D x H) |
112.6 x 78.4 x 84.1 in |
112.6 x 78.4 x 84.1 in |
|
2.86 x 1.99 x 2.13 m |
2.86 x 1.99 x 2.13 m |
| Spectrometer |
CDS 600 |
CDS 610 |
| Dimensions: |
89.1 mm x 63.3 mm x 34.4 mm |
89.1 mm x 63.3 mm x 34.4 mm |
| Pixels: |
2048 pixels |
2048 pixels |
| Pixel Size: |
14 µm x 200 µm 1 |
4 µm x 200 µm |
| Pixel Well Depth: |
~62,500 electrons |
~62,500 electrons |
| Sensitivity: |
75 photons/ |
75 photons/ |
|
count at 400 nm; |
count at 400 nm; |
|
41 photons/ |
41 photons/ |
|
count at 600 nm |
count at 600 nm |
| Focal Length: |
42 mm input; |
42 mm input; |
|
68 mm output |
68 mm output |
| Entrance Aperture: |
100 µm |
100 µm |
| Wavelength Aange: |
200-850 nm |
350-1000 nm |
| Signal-to-Noise Ratio: |
250:1 (at full signal) |
250:1 (at full signal) |
| A/D Resolution: |
16 bit |
16 bit |
| Dynamic Range: |
2 x 10^8 (system) |
2 x 10^8 (system) |
| Integration Time: |
8 ms to 20 seconds |
8 ms to 20 seconds |
| Stray Light: |
<0.05% at 600 nm; |
<0.05% at 600 nm; |
|
<0.10% at 435 nm |
<0.10% at 435 nm |
| Corrected Linearity: |
>99.8% |
>99.8% |
|
|
|
| Power Supply |
LPS 150-0268 |
LPS 150-0268 |
| Power Requirements: |
110./220 VAC, 50/60 Hz |
110./220 VAC, 50/60 Hz |
| Current Stability: |
+/- 0.01% |
+/- 0.01% |
| Current Rise Time: |
20 +/- 5 seconds |
20 +/- 5 seconds |
| Regulated Current: |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
| Weight: |
6.5 lbs. (2.9 kg) |
6.5 lbs. (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
| CSLMS LED 76 inch Sphere |
CSLMS LED 7660 |
CSLMS LED 7661 |
| Choice Spectral Light Measurement System |
AS-02481-800 |
AS-02481-900 |
|
|
|
| System Includes: |
|
|
| Lamp Measurement Sphere, 76 inch: |
AS-02481-000 |
AS-02481-000 |
| CCD Spectrometer, CDS 600 or 610: |
AS-02767-000 |
AS-02767-100 |
| Spectral Calibrated Lamp SCL-1400: |
AS-01342-000 |
AS-01342-000 |
| Lamp Power Supply, LPS-150-0268: |
AS-02656-268 |
AS-02656-268 |
|
|
|
| Software required, sold separately |
|
|
| MtrX-SPEC Spectral Light Measurement Software® |
Light MtrX® |
LightMtrX® |
|
|
|
| System Properties and Performance |
|
|
|
|
|
| Light Measurement Sphere: |
LMS-7600 |
LMS-7600 |
| Sphere Diameter: |
76 in (1.93 m) |
76 in (1.93 m) |
| Sphere Coating Reflectance: |
98% |
98% |
| Radiometric Range: |
5,000 W (max) |
5,000 W (max) |
| Photometric Range: (Illuminant A) |
0.08 – 260,000 lm |
0.08 – 260,000 lm |
| Red LED Range: |
1.7 – 93,000 lm |
1.7 – 93,000 lm |
| Green LED Range: |
2.0 – 10,000 lm |
2.0 – 10,000 lm |
| Blue LED Range: |
0.70 – 32,000 lm |
0.70 – 32,000 lm |
| Max Recommended Lamp Dimension: |
8 x 8 in (21 x 21 cm) |
8 x 8 in (21 x 21 cm) |
| Maximum Tubular Lamp Length: |
52 in (1.3 m) |
52 in (1.3 m) |
| Sphere Dimension: (W x D x H) |
116.9 x 88.2 x 91.4 in |
116.9 x 88.2 x 91.4 in |
|
2.97 x 2.24 x 2.32 m |
2.97 x 2.24 x 2.32 m |
|
|
|
| Spectrometer |
CDS 600 |
CDS 610 |
| Dimensions: |
89.1 mm x 63.3 mm x 34.4 mm |
89.1 mm x 63.3 mm x 34.4 mm |
| Pixels: |
2048 pixels |
2048 pixels |
| Pixel Size: |
14 µm x 200 µm |
14 µm x 200 µm |
| Pixel Well Depth: |
~62,500 electrons |
~62,500 electrons |
| Sensitivity: |
75 photons/ |
75 photons/ |
|
count at 400 nm; |
count at 400 nm; |
|
41 photons/ |
41 photons/ |
|
count at 600 nm |
count at 600 nm |
| Focal Length: |
42 mm input; |
42 mm input; |
|
68 mm output |
68 mm output |
| Entrance Aperture: |
100 µm 1 |
00 µm |
| Wavelength Range: |
200-850 nm |
350-1000 nm |
| Signal-to-Noise Ratio: |
250:1 (at full signal) |
250:1 (at full signal) |
| A/D Resolution: |
16 bit |
16 bit |
| Dynamic Range: |
2 x 10^8 (system) |
2 x 10^8 (system) |
| Integration Time: |
8 ms to 30 seconds |
8 ms to 30 seconds |
| Stray Light: |
<0.05% at 600 nm; |
<0.05% at 600 nm; |
|
<0.10% at 435 nm |
<0.10% at 435 nm |
| Corrected Linearity: |
>99.8% |
>99.8% |
|
|
|
| Power Supply |
LPS 150-0268 |
LPS 150-0268 |
| Power Requirements: |
110./220 VAC, 50/60 Hz |
110./220 VAC, 50/60 Hz |
| Current Stability: |
+/- 0.01% |
+/- 0.01% |
| Current Rise Time: |
20 +/- 5 seconds |
20 +/- 5 seconds |
| Regulated Current: |
2.679 A +/- 0.1% |
2.679 A +/- 0.1% |
| Weight: |
6.5 lbs. (2.9 kg) |
6.5 lbs. (2.9 kg) |
| Dimension: (W x D x H) |
8.3 x 10.5 x 3.5 in |
8.3 x 10.5 x 3.5 in |
|
21.1 x 26.7 x 8.9 cm |
21.1 x 26.7 x 8.9 cm |
| Compliance: |
CE |
CE |
|
|
|
Optional Accessories for CSLMS LED Systems
|
|
|
| LS Series LED Sockets |
Choose your own |
|
| I 1000 Condition B Intensity Head |
AS-02700-100 |
|
| I 2000 Condition A & B Intensity Head |
AS-02700-316 |
|
| E 1000 Spectral Irradiance Head |
AS-02700-000 |
|
| IES 1000 Intensity/Irradiance Calibration Lamp Standard |
AS-02700-602 |
|
| CAL-LX-IRR Calibration of E 1000 with Light MtrX and Spectrometer |
CAL-LX-IRR |
|
| CAL-LX-INT Spectral Intensity Calibration |
CAL-LX-INT |
|
| Absorption Correction Lamp, AUX-100 |
AS-02737-000 |
|
| Preset Power Supply, LPS-100-0833, 8.33A 100W |
AS-02600-833 |
|
| Calibrated Spectral Flux Set, CSFS-1400 |
AS-01343-000 |
|
| Horizontal Lamp Mount Bracket |
AS-02477-003 |
|
| Temperature Probe, TP-400 |
AS-02637-400 |
|
| Temperature Probe and Monitor, TPM-400 |
AS-02638-400 |
|
|
|
Print PDF of this page



|
|