Radiometer/Photometer
FEATURES:
- Compatibility with Si, Ge, InGaAs, and many other Photovoltaic Detectors
- Dynamic Range of 8 Decades of Sensitivity
- Stores up to 100 Photometric and Radiometric Calibration Constants
- 32 Output Lines for Computer Control of System Peripherals
- TC/IP, DHCP Computer Connections
APPLICATIONS:
- Controlling Calibration Systems
- Photometric and Radiometric Monitoring of Camera Calibration Systems
- Lamp Measurement
- Photometry
- Laser Power Measurement
Download Datasheet
Labsphere's SC 6000 System Controller is a programmable radiometer/photometer that allows for up to 100-programmed calibrations. Labsphere will calibrate the SC 6000 to monitor luminous and radiant flux, luminance, radiance, intensity, illuminance and irradiance, making it an integral component of any calibration system.
Use the SC 6000 across a range of applications such as a uniquely designed imaging calibration instrument, a lamp measurement photometer, or a laser power measurement system.
The SC 6000 is both a highly flexible, programmable radiometer/photometer and a system controller. The integrated microprocessor-based controller is the communication hub for Labsphere's power supplies. With a variety of interchangeable detector assemblies, integrating spheres and components, light sources, and power supplies, you are able to create, upgrade or expand a calibration system in minutes.
The SC 6000 operates out-of-the-box. A 64 -digit backlit LCD display allows you to view measurement results, select calibration factors, and set display features and remote communication parameters. Operation features include up to 100 programmable optical radiation calibrations, manual and auto ranging, digital or analog display, digital filtering, 5 -digit display, display zero, and display normalization display.
ORDERING INFORMATION AND SPECIFICATIONS
| Model and Description |
Order Number |
| System Control Radiometer/Photometer |
AS-02702-000 |
| Properties and Performance |
|
Current Dynamic Range:
|
8+ decades; 1pA - 20mA |
Display Resolution:
|
5 digits |
Maximum Reading Rate:
|
5 readings/second |
Input:
|
Single Channel |
Input Connector:
|
BNC |
Input Bias:
|
+14 VDC Selectable |
Input Impedance:
|
0 O Single ended |
Compatible Detectors:
|
Photovoltaic (Si, Ge, InGaAs) |
ADC Resolution:
|
16 bits |
Nonlinearity:
|
± 1 count |
Temperature Coefficient:
|
± (0.02% of reading + 0.5 counts) per °C |
Operating Environment:
|
0° to 50°C, |
|
0% to 70% relative humidity at 35°C |
Calibration Digital:
|
factors are stored in the ROM memory |
Calibration Factors:
|
2 to 100 programmable coefficients |
Power Requirements:
|
12 VDC, 750 mADC maximum AC/DC Converter Provided 90 ~ 264 VAC, 47 ~ 63 Hz |
Computer Interface:
|
TCP/IP, DHCP |
Weight:
|
4.1 lbs (1.86kg) |
| Dimension: W x D x H |
1.75 x 8.25 x 10.5 in |
|
(4.4 x 20.9 x 26.4 cm) |
| Compatible Labsphere Detectors |
|
| SDA-050-U-RTA-CX Silicon Detector Assembly |
AS-02522-400 |
| SDA-050-P-RTA-CX Photopic Detector Assembly |
AS-02522-401 |
| IDA-050-RTA-CX InGaAs Detector Assembly |
AS-02522-402 |
| IDA-EXT-050-RTA-CX Extended InGaAs Detector Assembly |
AS-02522-403 |
| GDA-050-U-RTA-CX Germanium Detector Assembly |
AS-02522-404 |
|