Skip to content

HELIOS®Plus-AMA Air Mass-Albedo Sunlight Systems

Test as you fly. The ultimate expression of uniform calibration source technology.

Features:

·      Spectrums and levels equivalent to solar outputs
·      3000K to 6000K adjustable CCT and spectrum
·      Large dynamic range from albedo 0 (AM0) to night vision radiances
·      CDS Spectrometer for spectral monitoring
·      Angular uniform FOV 35° +/-2.0%

Contact for Pricing

The HELIOSPlus-AMA, A Family systems are the ultimate expression of uniform calibration source technology allowing you to test with spectrums and levels that are equivalent to solar outputs. The A Family allows you to confirm all your testing with classic QTH and augment your characterization to test as you fly with traceable solar-like light.

System Sphere Dia Port Dia Max Luminance, cd/m2 Illuminance at Port, lux CCT Range Variable Attenuator # Steps
USLR-A20F-XAN2-P 20 8 20,000 63,000 3000K – 6000K Advanced, VAA 2.00E+06
USLR-A20F-XDN2-P 20 8 20,000 63,000 3000K – 6000K Dynamic, VAD 1.20E+04
USLR-A20F-XMN2-P 20 8 20,000 63,000 3000K – 6000K Manual, VA-MM 1.00E+04
USLR-A12F-XAN2-P 12 4 37,500 117,800 3000K – 6000K Advanced, VAA 2.00E+06
USLR-A12L-XAN2-P 12 4 47,300 148,200 3000K – 6000K Advanced, VAA 2.00E+06
USLR-A12L-UAN1-P 12 4 32,500 102,000 3000K – 6000K Advanced, VAA 2.00E+06
USLR-A12F-XDN2-P 12 4 42,000 84,000 3000K – 6000K Dynamic, VAD 1.20E+04
USLR-A12L-XDN2-P 12 4 58,000 182,000 3000K – 6000K Dynamic, VAD 1.20E+04
USLR-A12L-UDN1-P 12 4 32,000 100,800 3000K – 6000K Dynamic, VAD 1.20E+04
USLR-A12F-XMN2-P 12 4 42,000 78,000 3000K – 6000K Manual, VA-MM 1.00E+04
USLR-A12L-XMN2-P 12 4 58,000 182,000 3000K – 6000K Manual, VA-MM 1.00E+04
USLR-A12L-UMN1-P 12 4 32,000 100,800 3000K – 6000K Manual, VA-MM 1.00E+04

Specifications

If you are working with satellite or airborne field imaging and sensing systems and need solar spectrums for your testing needs, there’s a HELIOSPlus A Family system for you.

USLR-A20F-XAN2-P

  • Expected Max Luminance 20,000 cd/m2 (Xe and QTH)
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Advanced Variable Attenuator, VAA-220A
  • Number of Steps in System Range 2.00E+06 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 4.41E+07/25/152
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A20F-XDN2-P

  • Expected Max Luminance 20,000 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Dynamic Variable Attenuator, VAD-012
  • Number of Steps in System Range 1.20E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 4.85E+04/15/93
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A20F-XMN2-P

  • Expected Max Luminance 20,000 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Manual Micrometer Variable Attenuator, VA-MM
  • Number of Steps in System Range 1.00E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 2.20E+05/17/106
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A12F-XAN2-P

  • Expected Max Luminance 37,500 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Advanced Variable Attenuator, VAA-220A
  • Number of Steps in System Range 2.00E+06 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 2.68E+07/24/148
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A12L-XAN2-P

  • Expected Max Luminance 47,300 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Advanced Variable Attenuator, VAA-220A
  • Number of Steps in System Range 2.00E+06 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 3.37E+07/25/150
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A12F-XDN2-P

  • Expected Max Luminance 37,500 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Dynamic Variable Attenuator, VAD-012
  • Number of Steps in System Range 1.20E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 2.95E+04/14/89
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A12L-XDN2-P

  • Expected Luminance 47,300 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Dynamic Variable Attenuator, VAD-012
  • Number of Steps in System Range 1.20E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 3.71E+04/15/91
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A12F-XMN2-P

  • Expected Max Luminance 37,500 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Manual Micrometer Variable Attenuator, VA-MM
  • Number of Steps in System Range 3.00E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 4.31E+05/17/111
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A12L-XMN2-P

  • Expected Luminance 47,300 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+200K/-400K)
  • Variable Attenuator Manual Micrometer Variable Attenuator, VA-MM
  • Number of Steps in System Range 1.00E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 1.48E+05/17/102
  • Spectrometer Spectral Range 350 - 1000 nm

USLR-A12L-UAN1-P

  • Expected Max Luminance 32,000 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+/-300K)
  • Variable Attenuator Advanced Variable Attenuator, VAA-220A
  • Number of Steps in System Range 2.00E+06 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 2.32E+07/24/146
  • Spectrometer Spectral Range 200 - 850 nm

USLR-A12L-UDN1-P

  • Expected Max Luminance 32,000 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+/-300K)
  • Variable Attenuator Dynamic Variable Attenuator, VAD-012
  • Number of Steps in System Range 1.20E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 2.55E+04/14/88
  • Spectrometer Spectral Range 200 - 850 nm

USLR-A12L-UMN1-P

  • Expected Max Luminance 32,000 cd/m2
  • CCT Range 3000K (+/-50K) to 6000K (+/-300K)
  • Variable Attenuator Manual Micrometer Variable Attenuator, VA-MM
  • Number of Steps in System Range 1.00E+04 (#lamps*VA Steps)
  • Dynamic Range/Bits/dB 1.02E+05/16/99
  • Spectrometer Spectral Range 200 - 850 nm
  • Dynamic Range/Bits/dB 1.48E+05/17/102